EasyManua.ls Logo

Polycom 1500 - Page 155

Polycom 1500
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5-Deploying a Polycom RMX™ Serial Gateway S4GW
Polycom, Inc. 5-17
NumberOf
Repeat
Chars
Allowed
1-4 Sets the number of repeated characters
allowed in valid password.
Available Since V5.7.2
2
Min
NumberOf
Changed
Chars
1-4 Sets the minimum number of characters
needed to change when setting new
password.
Available Since V5.7.2
4
daysFor
Password
Expire
Notification
1-7 Sets the number of days before password
expires that a ‘password expiration notice’ will
be shown to user.
Available Since V5.7.2
7
password
ReuseBuff
Size
8-16 Sets the number of passwords saved to check
for reuse. i.e. if the buffer is set to 10, then the
user cannot re-useany of the last 10
passwords.
Available Since V5.7.2
10
user
LockedOut
Duration
0-480
minutes
Sets the number of minutes before user that
was locked out will be automatically released.
Value of 0 – means indefinite.
Available Since V5.7.2
0
user
Session
Limit
1-10
sessions
Sets the number of simultaneous sessions per
user allowed.
Available Since V5.7.2
5
auditLog
Threshold
10 -100
percent of
log capacity
Sets the audit log threshold, so that when this
value is reached an audit log overflow trap is
sent.
Available Since V5.7.2
70
Password
Expiration
Timeout
30-180 days Sets the number of days till password will
expire.
Available Since V5.7.2
60
User
Lockout
Failures
Interval
60-1440
minutes.
(1440 = 24
hours)
Period of time in which the failed login
threshold must be exceeded the lock the
users account.
Available Since V5.7.2
60
Table 5-3 Advanced Commands (Continued)
Command Parameters Description Default

Table of Contents

Other manuals for Polycom 1500

Related product manuals