Application > VGL Setup > Prop Line Length
This menu determines how the position of the next graphic element is
determines based on the string that precedes it.
Disable
The position of the next graphic element will be
determined as if the font was monospaced (all
characters had the same specified width).
Enable
The position of the next graphic element will be
determined by the physical length of a text string (when
using a proportional spaced font).
Factory Default
Enable
Application > VGL Setup > Printer PI
This menu determines how the PI line is configured in the LP+ emulation.
Disable
The LP+ Emulation is configured with the PI line
disabled.
Enable
The LP+ Emulation is configured with the PI line
enabled.
Factory Default
Disable
Application > VGL Setup > Host PI
This menu determines how the host PI line for the parallel interface is
configured.
Disable
The host does not send PI signals.
Enable
The host sends PI signals. The Data Bit 8 configuration
option must be disabled to transmit the PI line to the
printer.
Factory Default
Disable
Application > VGL Setup > Max PI 16
This menu determines the range of a paper slew from the PI line.
Disable
A paper slew of 1-15 will move 1-15 lines. A paper slew
of 0 will always move 1 line.
Enable
A paper slew of 0-15 will move 1-16 lines.
Factory Default
Enable