Table 21. Host Interface Characteristics
1. Serial RS-232 at 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or
115200 baud.
2.
USB 2.0
3.
Ethernet 10/100
4.
Wireless 802.11 a/b/g/n
5.
Parallel (Centronics compatible) or IEEE 1284 bi-directional.
The RS-232 host interfaces shall have the following
characteristics:
Selectable 7-bit or 8-bit data format
XON/XOFF (in receive mode only) and
CTS/DTR
Selectable from 1k through 16 kbytes.
XOFF is
transmitted and DTR goes low
when buffer is
equal to or less than 25%
of full. XON is
transmitted and DTR goes
high when buffer is
25% above empty.
Characters are transmitted
with no parity
from the printer
Table 22. Power Source and Grounding
115 or 230 VAC 50/60Hz switching power
supply.
Unit must be connected to a properly
grounded receptacle.
Table 23. Power Consumption
T6 in Thermal Transfer Print Mode, +15 Intensity, 120VAC 60Hz input,
22degC @ 40% RH