154
Application > P-Series XQ Setup > EVFU Select
Controls how the printer handles vertical formatting.
Disable
Disables all EVFU processing.
Enable
Selects P-Series compatible Electronic Vertical Format
Unit (EVFU).
Factory Default
Enable
Application > P-Series XQ Setup > Upr. Case Select
Controls how the printer handles lowercase characters it receives from the
host computer. When enabled, all characters are printed in uppercase.
Disable
Prints lowercase characters received from the host
computer as lowercase; prints uppercase characters
received from the computer as uppercase.
Enable
Prints lowercase characters received from the host
computer as their corresponding uppercase
equivalents; prints uppercase characters received
from the computer as uppercase.
Factory Default
Disable
Application > P-Series XQ Setup > Slew Relative
“Slewing” is rapid vertical paper movement. This parameter determines the
number of lines slewed (either 1-15 lines or 1-16 lines) when an EVFU Slew
Relative command is received.
1-15 lines
1-16 lines
Factory Default
1-15 lines
Application > Serial Matrix Setup
IMPORTANT The Serial Matrix Setup submenu will only be present when the LP+ Emulation
menu is set to Serial Matrix. Otherwise, this menu will be replaced with the LP+
Emulation menu.