148
Application > P-Series Setup > Auto LF
This option defines the printer action when print data is received past the
forms width setting.
Disable
Discards any data past the forms width.
Enable
Performs an automatic carriage return and line feed
when data is received past the forms width.
Factory Default
Disable
Application > P-Series Setup > Define LF Code
This option controls the action of the printer when it receives a Line Feed
code (0A hex) from the host computer. If this feature is enabled, each time
the printer receives a line feed, it inserts an additional carriage return code
(0D hex) into the data stream. Do not use this feature if the host computer
sends carriage returns to the printer.
LF = LF
Does not insert a carriage return before each line feed.
The next print position will be the current print position
of the next line.
LF = CR + LF
Inserts an extra carriage return before each line feed.
The next print position will be print position 1 of the
next line.
Factory Default
LF = CR + LF
Application > P-Series Setup > Control Code 06
Control Code 06 defines the function of ASCII code 06 hex (ACK). You can
select an alternate line spacing of 6.0, 8.0, or 10.3 LPI.
Selections
6.0, 8.0, or 10.3 LPI
Factory Default
8.0 LPI
Application > P-Series Setup > Control Code 08
Control Code 08 defines the function of ASCII code 08 hex (BS). You can
define the code to output an Elongated character or a Backspace.
Elongated
Output and Elongated character
Backspace
Output and Backspace character
Factory Default
Elongated