Chapter 6: Performing Library Operations
Unlocking and Opening the I/E Station
Quantum Scalar i40 and Scalar i80 User’s Guide 147
4 Within 30 seconds, open the I/E station by pulling outward on the
magazine bezel handle until the magazine stops moving.
If you do not open the magazine within 30 seconds, it locks and you
receive the following failure message.
Figure 27 I/E Station Locked
Message
5 When finished, push the magazine in completely.
The I/E station is now locked.
Web Client
1 Select Operations > I/E Station Unlock.
2 Sele
ct an I/E station to unlock and click Apply.
Note: Only closed I/E stations are listed.
3 Click Apply to confirm, and click OK.
The Progress Window displays. The Progress Window contains
information on the action, el
apsed time, and status of the
requested operation. Do one of the following:
•If Success appears in the Progress Window
, the I/E station was
unlocked. Click Close to close the Progress Window. The
operator panel displays the status Unlocking and then Idle.
•If Fa
ilure appears in the Progress Window, the I/E station did
not unlock.
4 Within
30 seconds, pull outward on the magazine bezel handle to
open the I/E station.
If you do not open the magazine within 30 seconds, it locks.

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g