Chapter 4: Configuring the Library
Setting the Date, Time, and Time Zone
48 Quantum Scalar i40 and Scalar i80 User’s Guide
For more information about the library MIB, see the
Scalar i40 and
Scalar i80 Basic SNMP Reference Guide
(6-66773-xx) or contact
Quantum Support.
For information on integrating MIBs with an SNMP management
application, contact your network management application vendor.
Web Client
1 Select Tools > Download SNMP MIB.
2 Save the file to a known location.
Setting the Date, Time, and Time Zone
You can either set the library date, time, and time zone settings
manually or configure the Network Time Protocol (NTP). NTP allows you
to synchronize the library date and time with other components in your
IT infrastructure.
If you enable NTP, you must also configure the IP address of at least one
NTP server. Contact your network administrator for NTP server IP address
information.
You can configure the date and time on both the operator panel and
the Web client. You can view the time zone on the operator panel, but
must use the Web client to change it. You can only configure NTP
settings on the Web client.
Note: The following operations should not be performed
concurrently by multiple administrators logged in from
different locations. You can access the appropriate screens, but
you cannot apply changes while another administrator is
performing the same operation.

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g