Viewing the Network Settings Report
214 Quantum Scalar i40 and Scalar i80 User’s Guide
Note: Do not enter more than one e-mail address in the E-mail
Address
text box on the Tools - E-mail Configuration Record
screen. If you need to send the configuration record to multiple
e-mail addresses, repeat the procedure for each e-mail address.
Before you can e-mail the configuration record, the library e-mail
account must be configured. For information on setting up the e-mail
account, see
Configuring the Library E-Mail Account on page 76.
You can only e-mail the library configuration record from the Web
client.
Web Client
1 Select Tools > E-mail Configuration Record.
2 Type an e-mail address into the E-mail Address text box.
3 Click Apply.
Viewing the Network Settings Report
The Network Settings report provides information on the following
library settings:
Network — Host name, primary DNS, and alternate DNS
IPv4 Settings — DHCP enabled/disabled, IP address, gateway, and
netmask
IPv6 Settings (if IPv6 is enabled) — DHCP enabled/disabled,
stateless configuration enabled/disabled, static configuration
enabled/disabled, net prefix, gateway, and all IPv6 addresses
SSL — SSL, port, and cipher
SMI-S — Access (enabled/disabled) and state (enabled/disabled)
SNMP — Enabled/disabled status for Access, V1, V2, V3, and
encryption; algorithm; and port
SNMP-Traps — IP addresses and ports

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g

Related product manuals