Appendix B: Tape Alert Flag Descriptions
Quantum Scalar i40 and Scalar i80 User’s Guide 353
20 Cleaning
required
C The tape drive needs cleaning:
1 If the operation has stopped, eject
the tape and clean the drive.
2 If the operation has not stopped,
wait for it to finish and then clean
the drive.
Check the tape drive user’s manual for
device-specific cleaning instructions.
The drive thinks it
has a head clog or
needs cleaning.
21 Cleaning
requested
W The tape drive is due for routine
cleaning:
1 Wait for the current operation to
finish.
2 Then use a cleaning cartridge.
Check the tape drive user’s manual for
device-specific cleaning instructions.
The drive is ready for
a periodic cleaning.
22 Expired
cleaning media
C The last cleaning cartridge used in the
tape drive has worn out:
1 Discard the worn-out cleaning
cartridge.
2 Wait for the current operation to
finish.
3 Then use a new cleaning cartridge.
The cleaning
cartridge has
expired.
23 Invalid cleaning
tape
C The last cleaning cartridge used in the
tape drive was an invalid type:
1 Do not use this cleaning cartridge in
this drive.
2 Wait for the current operation to
finish.
3 Then use a valid cleaning cartridge.
Invalid cleaning
cartridge type used.
No. Flag Severity
Recommended Application Client
Message Probable Cause

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g

Related product manuals