Appendix B: Tape Alert Flag Descriptions
Quantum Scalar i40 and Scalar i80 User’s Guide 355
31 Hardware B C The tape drive has a hardware fault:
1 Turn the tape drive off and then on
again.
2 Restart the operation.
3 If the problem persists, call the tape
drive supplier help line.
The drive has a
hardware fault that
is not read/write
related or requires a
power cycle to
recover.
32 Primary
interface
W The tape drive has a problem with the
host interface:
1 Check the cables and cable
connections.
2 Restart the operation.
The drive has
identified an
interface fault.
33 Eject media C The operation has failed:
1 Eject the tape or magazine.
2 Insert the tape or magazine again.
3 Restart the operation.
Error recovery action.
34 Microcode
update fail
W The microcode update has failed
because you have tried to use the
incorrect microcode for this tape drive.
Obtain the correct microcode and try
again.
Microcode update
failed.
35 Drive humidity W Environmental conditions inside the
tape drive are outside the specified
humidity range.
Drive humidity limits
exceeded.
36 Drive
temperature
W Environmental conditions inside the
tape drive are outside the specified
temperature range.
Cooling problem.
37 Drive voltage W The voltage supply to the tape drive is
outside the specified range.
Drive voltage limits
exceeded.
38 Predictive
failure
C A hardware failure of the tape drive is
predicted. Call the tape drive supplier
help line.
Predictive failure of
drive hardware.
No. Flag Severity
Recommended Application Client
Message Probable Cause

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g