Command reference
R&S
®
ZNA
923User Manual 1178.6462.02 ─ 20
Parameters:
<EyeView> STIMulus | EMPHasis | JITTer | NOISe | DUT | EQUalization
The rightmost building block that shall be part of the calculation
chain STIMulus > EMPHasis > JITTer > NOISe > DUT > EQUali-
zation.
Note that the selected block must be active, for example
CALCulate1:EYE:VIEW JITTER requires
CALCulate<Chn>:EYE:JITTer:STATe to be ON.
Conversely, if CALCulate1:EYE:VIEW is set to JITTER and
subsequently CALCulate1:EYE:JITTer:STATe is turned
OFF, the calculation chain is further shortened to the next active
building block.
Options:
R&S ZNA-K20
Manual operation: See "[Slider]" on page 743
7.3.1.7 CALCulate:FILTer[:GATE]...
The CALCulate:FILTer[:GATE]... commands define the properties of the time
gate which is used to optimize the time domain response.
CALCulate:FILTer[:GATE]:TIME:AOFFset......................................................................... 923
CALCulate<Chn>:FILTer[:GATE]:TIME[:TYPE]..................................................................924
CALCulate<Chn>:FILTer[:GATE]:TIME:CENTer.................................................................924
CALCulate<Chn>:FILTer[:GATE]:TIME:DCHebyshev......................................................... 925
CALCulate<Chn>:FILTer[:GATE]:TIME:SHAPe..................................................................925
CALCulate<Chn>:FILTer[:GATE]:TIME:SHOW.................................................................. 926
CALCulate<Chn>:FILTer[:GATE]:TIME:SPAN....................................................................926
CALCulate<Chn>:FILTer[:GATE]:TIME:STARt...................................................................927
CALCulate<Chn>:FILTer[:GATE]:TIME:STOP................................................................... 927
CALCulate<Chn>:FILTer[:GATE]:TIME:STATe...................................................................927
CALCulate<Chn>:FILTer[:GATE]:TIME:WINDow............................................................... 928
CALCulate:FILTer[:GATE]:TIME:AOFFset <Boolean>
Activates the operating mode where the time gate is moved in the opposite direction
when the "Delay" setting is changed.
Parameters:
<Boolean> ON | OFF - enable or disable "Adjust Time Gate".
*RST: OFF