Section 12 Bus State Controller (BSC)
Rev. 4.00 Sep. 14, 2005 Page 307 of 982
REJ09B0023-0400
CS3WCR
Bit Bit Name
Initial
Value R/W Description
31 to 15 All 0 R Reserved
These bits are always read as 0. The write value
should always be 0.
14
13
WTRP1*
WTRP0
0
0
R/W
R/W
Number of Auto-Precharge Completion Wait Cycles
Specify the number of minimum precharge completion
wait cycles during the periods shown below.
From the start of auto-precharge to issuing of the
ACTV command for the same bank
From issuing of the PRE/PALL command to issuing
of the ACTV command for the same bank
Until entering the power-down mode or deep
power-down mode
From issuing of the PALL command to issuing of
the REF command in auto refreshing
From issuing of the PALL command to issuing of
the SELF command in self refreshing
The setting for areas 2 and 3 is common.
00: No cycle
01: 1 cycle
10: 2 cycles
11: 3 cycles
12 0 R Reserved
This bit is always read as 0. The write value should
always be 0.
11
10
WTRCD1
WTRCD0
0
1
R/W
R/W
Number of Wait Cycles between ACTV Command and
READ(A)/WRIT(A) Command
Specify the minimum number of wait cycles from
issuing the ACTV command to issuing the
READ(A)/WRIT(A) command. The setting for areas 2
and 3 is common.
00: No cycle
01: 1 cycle
10: 2 cycles
11: 3 cycles