SP Mode Tables
SM Appendix 4-3 D096
Appendix:
SP Mode
Tables
1105 7 Low Level 2-Center
[0 to 80 / 60 / 1°C/step]
1105 8 Low Level 2-End
1105 9 Thick-Center
[140 to 185 / 175 / 1°C/step]
1105 10 Thick-End
1105 11 Warm Up Low-Center
[140 to 180 / 170 / 1°C/step]
1105 12 Warm Up Low-End
1106
Display Fusing
1106 1 Displays the fusing temperature (center)
1107*
Fusing Soft Start
Adjusts the number of zero-cross cycles of the fusing lamp AC supply needed
to bring the fusing lamp power to 100% while bringing the lamp up to the
standby temperature or while copying. Increase this value if the machine is
experiencing sudden power dropouts (
Fusing Temperature Control).
1107 1
Warm Up Soft
Start
[0 = 10 cycles / 1 = 20 cycles / 2 = 50 cycles]
1107 2 Other Soft Start
[0 = 5 cycles / 1 = 10 cycles / 2 = 20 cycles]
1108*
Set-Fusing Start
[0 = 1s / 1 = 1.5s / 2 = 2s]
1108 1
Specifies the interval for fusing-temperature control ( Fusing Temperature
Control).
1109
Nip Band Check
1109 1
Checks the fusing nip band (
NIP Band Width Adjustment).