SP Mode Tables
D096 4-10 SM Appendix
2922*
Toner Supply Time
2922 1
[0.1 to 5.0 / 0.4 / 0.1 s/step]
Adjusts the toner supply motor ON time for Sensor 1 and Sensor 2 toner
supply mode. Accordingly, this setting is effective only if SP 2921 is set to "0"
or "1" Raising this value increases the toner supply motor ON time. Set to a
high value if the user tends to make many copies having high proportions of
solid black image areas (
Toner Density Control).
2923*
Toner Recovery Time
2923 1
[3 to 60 / 30 / 1 s/step]
Adjusts the toner supply motor ON time used during toner recovery from
Toner Near End or Toner End. This setting is effective only if SP 2921 is set to
"0" Since toner recovery is carried out in 3-second cycles, the input value
should be a multiple of 3 (3, 6, 9...). (
Toner Density Control)
2925*
Toner Supply Rate
2925 1
Adjusts the toner supply time for fixed toner supply mode. This setting is
effective only if SP 2921 is set to "2" or "3".[0 to 7 / 0]t = 200ms, and settings
are as follows
0 = t , 1 = 2t, 2 = 4t, 3 = 8t, 4 = 12t, 5 = 16t,
6 = on continuously, 7 = 0 s
Raising this value increases the toner supply motor ON time. Set to a high
value if the user tends to make many copies having high proportions of solid
black image areas (
Toner Density Control).
2926*
Standard Vt
2926 1
[0.00 to 5.00 / 2.50 / 0.01 V/step] DFU
Adjusts Vts (the Vt value for new developer). The TD sensor output is
adjusted to this value during the TD sensor initial setting process]. This SP is
effective only when SP 2921 is "0", "1", or "2".