Data Management
R&S
®
ESW
273User Manual 1177.6298.02 ─ 08
These functions are only available if no measurement is running.
In particular, if a continuous measurement is active, the import/export functions are not
available.
Import..........................................................................................................................273
Export..........................................................................................................................273
Trace Export Configuration........................................................................... 273
I/Q Export......................................................................................................273
File Explorer........................................................................................273
Import
Access: "Save/Recall" > Import
Provides functions to import data.
Export
Access: "Save/Recall" > Export
Opens a submenu to configure data export.
Trace Export Configuration ← Export
Opens the "Traces" dialog box to configure the trace and data export settings.
Chapter 11.3.3, "Trace Export", on page 211
I/Q Export ← Export
Opens a file selection dialog box to define an export file name to which the I/Q data is
stored. This function is only available in single sweep mode.
"File Explorer": Instead of using the file manager of the R&S ESW firmware, you can
also use the Microsoft Windows File Explorer to manage files.
It is only available in applications that process I/Q data, such as the I/Q Analyzer or
other optional applications.
For details, see the description in the R&S ESW I/Q Analyzer User Manual ("Importing
and Exporting I/Q Data").
Note: Storing large amounts of I/Q data (several Gigabytes) can exceed the available
(internal) storage space on the R&S ESW. In this case, it can be necessary to use an
external storage medium.
Note: Secure user mode.
In secure user mode, settings that are stored on the instrument are stored to volatile
memory, which is restricted to 256 MB. Thus, a "memory limit reached" error can occur
although the hard disk indicates that storage space is still available.
To store data permanently, select an external storage location such as a USB memory
device.
For details, see Chapter 4.7, "Protecting Data Using the Secure User Mode",
on page 40.
File Explorer ← I/Q Export ← Export
Opens the Microsoft Windows File Explorer.