3. Perform a prinng test to check the results.
Procedure
1. Load the media.
P. 30「Setup of Media」
2. Press [FUNCTION].
3. Press [▼], then [▶] to display the screen shown below.
4. Press [ENTER].
Prinng of the test paern starts.
5. Check whether there is dot drop-out or dot displacement in the test paern.
Missing blocks indicate dot drop-out. Collapsed or inclined blocks indicate dot displacement.
6. If you have opened the front cover, close it.
If no dot drop-out or dot displacement occurs, this operaon is nished. Press [FUNCTION] to go back to the
original screen.
If dot drop-out or dot displacement is present, perform medium cleaning.
If the results are sll the same even aer you perform super cleaning a few mes, contact your authorized Roland
DG Corporaon dealer.2
Handling Severe Dot Drop-out and Dot Displacement
3. Advanced Maintenance 251