EasyManua.ls Logo

Roland TrueVIS VG2-540 - Error Messages; Align Point Position Invalid; Option Dryer Is Not Connected; Temperature Is too Low **°C

Roland TrueVIS VG2-540
319 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
This secon describes the error messages that may appear on the machine's display, and how to take acon to
remedy the problem. If the acon described here does not correct the problem or if an error message not descri-
bed here appears, contact your authorized Roland DG Corporaon dealer.
ALIGN POINT POSITION INVALID
An aempt was made to set an align point at a locaon where the seng cannot be made.
No align point can be set such that the angle between the base point and the align point is too large. Reload the
media correctly, so that the angle is minimized, and then set the base point and the align points again to match
the crop marks.
RELATED LINKS
  P. 110 "How to Cut with Crop Marks"
OPTION DRYER IS NOT CONNECTED
When [OPTION DRYER] is set to "ENABLE" with no auxiliary drying unit connected to the printer.
Switch the sub power and main power o, and then connect the auxiliary drying unit to the printer.
TEMPERATURE IS TOO LOW **°C
The temperature of the locaon where the machine is installed has fallen below the ambient temperature at
which the machine can operate.
Operaon cannot be connued. Turn o the sub power. The displayed temperature is the current ambient temper-
ature of the installaon locaon. Bring the installed locaon to a temperature at which operaon is possible (20 to
32°C [68 to 90°F]), allow the machine to come to room temperature, and then turn on the power.
TEMPERATURE IS TOO HIGH **°C
The temperature of the locaon where the machine is installed has risen above the ambient temperature at
which the machine can operate.
Operaon cannot be connued. Turn o the sub power. The displayed temperature is the current ambient temper-
ature of the installaon locaon. Bring the installed locaon to a temperature at which operaon is possible (20 to
32°C [68 to 90°F]), allow the machine to come to room temperature, and then turn on the power.
CROPMARK ERROR NOT FOUND
Automac detecon of crop marks could not be accomplished.
Load the media at the correct posion and perform detecon of crop marks again. If repeang automac crop-
mark detecon results in an error again, perform manual crop-mark detecon. If crop marks cannot be detected
even manually, try using [CROP SENSOR ADJ.] (the correcon funcon of the sensor for reading crop marks) to
perform the correcon. Depending on the media, it may not be possible to detect crop marks automacally.
RELATED LINKS
  P. 110 "How to Cut with Crop Marks"
  P. 174 "Aligning the Posions of Cung with Crop Marks Manually"
  P. 184 "Correct the sensor for reading crop marks."
  P. 281 "Automac Detecon of Crop Marks Fails"
CAN'T PRINT CROP CONTINUE?
1. The size of the data including the crop marks is larger than the prinng area of the loaded media.
2. The size of the data being output is too small.
Error Messages
300 5. Messages on the Operation Panel

Table of Contents

Other manuals for Roland TrueVIS VG2-540

Related product manuals