Adjusng the Level of the Sensor for Reading Crop Marks According to the Media
When the sensor for reading crop marks is corrected, the correcon value is stored. When using another media,
adjust the level of the sensor for reading crop marks, as the correcon value may not match.
Procedure
1. Press [MENU].
2. Press [▲] to display the screen shown below.
3. Press [▶] once, and then press [▼] twice to display the screen shown below.
CUTTING MENU
CROPSENS CALIB.
4. Press [▶], then [▼] to display the screen shown below.
5. Press [▶] twice to display the screen shown below.
6. Press [▲] or [▼] to set the correcon value.
7. Press [ENTER] to conrm your entry.
8. Press [MENU] to go back to the original screen.
Accurately Adjusting the Settings for Cutting with Crop Marks