Correcng the Misalignment of the Prinng and Cung Posions during Cung
This method pauses a cung operaon to correct the misalignment of the prinng and cung posions. The
correcon values set here are applied as the default values of the prinng and cung posions.
If the prinng and cung posions are misaligned, you normally adjust the posions while checking a test pat-
tern.
P. 169「Correcng the Misalignment of Prinng and Cung」
Procedure
1. During cung, press [PAUSE] to display the screen shown below.
TO CANCEL HOLD
DOWN PAUSE KEY
The cung operaon is paused.
2. Press [FUNCTION].
3. Press [▼] several mes to display the screen shown below.
4. Press [▶] once, and then press [▼] several mes to display the screen shown below.
5. Press [▶].
6. Determine the correcon values.
MEMO
Determine the values so as to correct the misalignment of the cung posion (
) in relaon to the prinng posion ( ). In
the case of the following gure, feed direcon "F" is misaligned in a negave direcon and scan direcon "S" in a posive
direcon. Therefore, set the correcon values for the feed direcon "F" to posive values and the scan direcon "S" to negave
values. Measure the actual misalignment amount when determining the value.
7. Set the correcon values for the feed direcon "F" and the scan direcon "S."
(1) Press [▲] or [▼] to set the correcon value for the feed direcon (F).
F:+0.30 +0.35mm
S:-0.40 -0.45mm
(2) Press [◀] or [▶] to set the correcon value for the scan direcon (S).
F:+0.30 +0.35mm
S:-0.40 -0.45mm
(3) When you have nished seng the correcon values, press [ENTER].
8. Press [PAUSE] to display the screen shown below.
Accurately Adjusting the Settings for Printing and Cutting
172 1. Optimizing the Output Quality