Doing so may cause re.
CAUTION
To store discharged uid temporarily, place it in the included drain bole or in a du-
rable sealed container such as a metal can or polyethylene tank, and cap the
container ghtly.
Any spillage or vapor leakage may cause re, odor, or physical distress.
IMPORTANT
Dispose of discharged uid properly, in accordance with the laws in eect in your locale.
Discharged uid is ammable and contains toxic ingredients. Never aempt to incinerate discharged uid or discard it with
ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams. Doing so may have an adverse impact on the
environment.
8. Quickly aach the emped drain bole to the machine once more.
9. Open the right cover.
10. Replace the tray pad.
IMPORTANT
Place the tray pad with an orientaon that matches the shape of the wiper tray. If you place the tray pad with the incorrect
orientaon, it will not be possible to clean the wiper correctly.
11. Close the right cover.
12. Press [ENTER].
The screen shown below appears, and then the machine is lled with TR2 cleaning liquid. The (approximate)
remaining me for the procedure is displayed on the screen. (The display shown below is an example.
"01:45" = "1 minute and 45 seconds")
FILLING LIQUID
>>>>> 01:40
If the TR2 cleaning liquid runs out during lling, the screen shown below appears. Replace the TR2 cleaning
liquid pouch. When you replace the wiper cleaning liquid pouch, the display returns to the original screen.
P. 58TR2 Cleaning Liquid Pouch Replacement
CHANGE CL-LIQUID
FOR WIPER
When the following screen is displayed again, the wiper tray cleaning is nished.