4 Operation and Configuration
96
SG112-ex Operator Manual
DEFAULT ROUTER
Set the default router of IPv6.
Note
Shows only if the LAN interface is selected.
PORT NUMBER
Set the LAN port numbers, 1 to 3.
The setting range is from 00001 to 65535.
The setting details is as follows:
Note
Shows only if the LAN interface is selected.
Each port (1, 2 and 3) must be set to different values.
When changing the port number, it is recommended to set to 1024 and
above.
The setting will be effective only if you power on the product again.
PROTOCOL
Set the communication protocol.
STATUS3: When selected, the product will proceed to the IGNORE
CR/LF screen.
STATUS4: When selected, the product will proceed to the STATUS
REPLY TIMING screen.
STATUS5: When selected, the product will proceed to the ITEM NO.
CHECK screen.
Port Number Initial
Value
Description
Status 3, 5 Status 4
1 1024 Bi-Directional Port Input port
2 1025 Not applicable Output port
3 9100 Bi-Directional Port Bi-Directional Port