Chapter 6: Using the Background Menu
Utilities Menu
114 Scantron OpScan 4ES and iNSIGHT 4ES Scanners
Description This dialog allows you to run the top head calibration
program.
Press Next to skip this function and to advance to the
next menu item.
The following describes how to calibrate the top read
head.
Calibration automatically adjusts the scanner read
system to compensate for variations in scanner
components, etc. Your scanner comes calibrated and
ready for use.
You should calibrate if you have:
• Received a Recalibrate Scanner message on the
scanner display
• Moved the scanner to a new location.
• Been instructed to do so by Scantron Customer
Support.
For best results, perform the following before
calibrating:
• Clean the scanner and the read heads. See Chapter
8, “Cleaning the Scanner” for details.
• Ensure that the calibration sheets are clean and
undamaged.
Press Run to calibrate the top read head. The following
menu item appears.
NOTE: iNSIGHT 4ES scanners require ten calibration
sheets for calibration.
NOTE: If you run out of calibration sheets, reload the
ones that are in the output tray.