Troubleshooting
250
Warning#
Number
Warning message (click description for more information)
WRN53
Conflicting digital inputs are turned on
WRN54
Fan circuit warning
Blower circuit overloaded or disconnected
WRN55
Excessive electrical noise warning
System produces excessive electrical noise
WRN56
Feedback type mismatch
The configured feedback type and the connected encoder do
not match
WRN57
sensAR encoder over-temperature warning
sensAR encoder over-temperature warning
WRN58
sensAR encoder built-in flash memory failure
sensAR built-in flash memory failure
WRN59
An excessively high axis shift is detected.
The device has detected abnormally high axis shift
WRN60
Gantry paired axis positive limit switch
The second gantry axis has reached the forward hardware or
software limit switch
WRN61
Gantry paired axis negative limit switch
The second gantry axis has reached the negative hardware or
software limit switch
WRN62
Internal axis synchronization lost (without HMI)
Internal FPGA communication synchronization problem
WRN63
Motor foldback disabled
WRN64
A connection between the controller and the drive is
removed
Reconnect the controller and drive
WRN65
LOAD failure parameter set to default value
LOAD failure parameter set to default value
WRN66
Inter-drive communication warning
There is a synchronization loss or timeout error at the inter-
drive communication layer
WRN67
Too many communication errors
Too many consecutive errors, check errors , or timeout errors
WRN68
Gantry does not receive PFB reply from partner axis
The axis sends position feedback data to the partner axis, but
the partner axis does not acknowledge receipt.
WRN69
Multi-turn encoder battery voltage low
During the secondary feedback, the battery voltage is close to
the fault level. Replace the battery as soon as possible.
WRN70
Knlusergain switch threshold configured incorrectly
Knlusergain switch threshold configured incorrectly

Table of Contents