7.19 Service
7.19.1 Device restart
If you have problems with the device, you can restart the device or subsections of the
de
vice (safety function, connections, additional functions).
Restarting safety function
T
he fastest type of restart
Serious faults remain, even if the cause has been rectified (for example a locking
state because of a supply voltage which is too low).
Communication with the device remains intact (connections for configuration,
safety function and data not relating to safety).
Communication beyond the device is not impaired.
Restarting safety function and connections
T
he device’s function is also re-established after serious faults if the cause has
been rectified.
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety). The device sets up communication
again automatically after restarting.
Communication beyond the device is not impaired.
Restarting device completely
T
he device behaves exactly as it does when the voltage supply is switched off and
back on again.
The device’s function is also re-established after serious faults if the cause has
been rectified.
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety).
Communication beyond the device is interrupted. This may also affect devices
which communicate beyond the device.
7.19.2 Factory settings
Overview
Be
fore reconfiguring the device, you can reset all settings to factory settings.
Depending on the device, 2 or 3 options are available.
Devices with 2 options for resetting to factory settings
R
esetting safety function to factory settings
The configuration for the safety function is reset to factory settings.
Communication beyond the device is not impaired.
Resetting complete settings to factory settings
The configuration for the safety function is reset to factory settings.
The configuration of device communication is reset to factory settings (connec‐
tions for configuration, safety function and data not relating to safety).
Devices with 3 options for resetting to factory settings
R
esetting safety function to factory settings
The configuration for the safety function is reset to factory settings.
Communication beyond the device is not impaired.
CONFIGURATION 7
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
129
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m