b
Ent
er an application name.
User name
T
he optional user name helps later users to find a contact for the application.
b
Enter a user name.
Application image
An ima
ge helps to identify the application more quickly. The application image is saved
in the project file on the PC and transmitted to the device. The Safety Designer sup‐
ports the following file formats: BMP, GIF, JPG, PNG, TIF.
1. Click on the pencil icon.
2. Select an image file for the application.
The image is incorporated as a thumbnail.
Description
A de
scription makes it easier to understand an application’s context more quickly.
b
Enter a description with a maximum of 1000 characters.
7.7 Protocol settings
7.7.1 PROFINET
F-destination address
F
or PROFIsafe communication, the safety laser scanner needs a unique F destination
address (F_Dest_Add). The same F destination address must be used here as in the
configuration of the controller.
b
Please enter a whole number between 1 and 65,534.
7 C
ONFIGURATION
98
O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET 8021219/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m