18.4 Mounting methods for protection from interference from systems in close proxim‐
it
y
Mutual interference of several safety laser scanners is unlikely thanks to the safeHDDM
sc
anning technology. You can choose a suitable mounting method to guarantee partic‐
ularly high availability or to avoid interference with laser scanners that do not have
safeHDDM functionality. In many cases, you can use the following examples as a guide.
NOTE
Y
ou must comply with the standard ISO 13855 when choosing the mounting method.
Mount several safety laser scanners offset and parallel to one another
100 mm
Figure 101: Mounting 2 safety laser scanners with the optics cover facing upward
100 mm
Figure 102: Mounting 2 safety laser scanners with the optics cover facing downward
ANNEX 18
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
201
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m