Connection
C
onnection status
18)
Type of connection
Checksums
A c
hecksum is used as a unique identification for a configuration. Using the checksum,
it is possible to work out whether a setup was changed or whether two devices have the
same configuration.
The checksum of the configuration in the project may not match the checksum in the
device, for example if a field geometry has been modified, but not yet transmitted to the
device.
If a process image with check of F_iPar_CRC is used, the F_iPar_CRC value must be
provided in the software configuration.
F_iPar_CRC is output at the following points:
In Safety Designer, Overview, Checksum of the configuration (function and network) dialog
box
In Safety Designer, Report dialog box, Checksum of the configuration (function and
network) (the character string can be highlighted and copied into the report)
In the I&M data record 4 (IM_Signature)
System status
Applic
ation status
Current notification of the safety laser scanner
Configuration date for the configuration in the device
Synchronization: shows whether the configuration in Safety Designer and the con‐
figuration in the device are identical
Verification status of the configuration in the project
Verification status of the configuration in the device
Time synchronization
C
onfigured value in the project
Configured values in the device
Measurement data
S
hows the measurement data when a device is connected.
Display
S
hows the status of the display and LEDs when a device is connected.
Establishing connection
1.
Check whether the safety laser scanner is connected correctly.
2. Click on Connect in the toolbar.
Safety Designer establishes the connection to the safety laser scanner.
7.3.1 Functional scope
Older versions of the Safety Designer potentially do not support the full functionality of
t
he latest devices. Vice versa, older devices might not support the full functionality of
the latest Safety Designer.
To identify the different levels of the functionality, we use a 3-digit version number. The
version number is marked with the letter V on the device.
18)
If t
he device is only connected via the network and has no network address, Safety Designer can find the device but cannot establish a
connection to it. You first need to assign the device a valid network address.
7 C
ONFIGURATION
92
O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET 8021219/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m