You can configure the way in which the device behaves when secure communication
is r
eestablished in the network after an interruption:
Manual start through “Restart safety function” action
After canceling secure communication, the safety function is stopped and the
device reports an application error. Once the connection is reestablished, you
must, in addition to reintegration by the controller, send the command Restart
safety function to the device via the process image or via the Safety Designer.
Aut
omatic start after connection
After aborting the safe communication, the safety laser scanner signals to W
ait for
inputs. As soon as the connection has been reestablished and the reintegration
has taken place, the device automatically switches to the current monitoring case.
No additional command is required.
Restart behavior
You define whether the internal restart interlock of the network outputs is used.
Available network outputs
S
afety Designer displays which network outputs are available.
If you have not specified an input source, you can specify the network output here.
7.13 Monitoring cases
Overview
Figure 75: Monitoring cases
1
Add monitoring case table
CONFIGURATION 7
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
119
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
BrandSICK
ModelmicroScan3
CategoryScanner
LanguageEnglish

Related product manuals