Page #70 background imageLoading...
Page #70 background image
Complementary information
In addit
ion to the safety-related PROFIsafe process image, you can use a non-safety-
related PROFINET process image at the output of the device (input of the control).
Information on using the non-safety-related PROFINET process image:
The PROFINET process image is available with a length of 12 or 6 Bytes.
The PROFINET process image must have the same length as the PROFIsafe proc‐
ess image.
The content of the PROFINET process image is identical to the content of the
PROFIsafe process image.
The PROFINET process image must not be used for safety-related tasks.
When using the PROFINET process image, the user must set a timeout appropriate
for the specific application in the control.
Further topics
"Pr
ocess images in detail", page 177
4.6 Testing plan
The protective device must be tested by appropriately qualified safety personnel when
commis
sioning, after modifications and at regular intervals.
The manufacturer and user must define the type and frequency of the thorough checks
of the machine on the basis of the application conditions and the risk assessment.
Determination of the thorough checks must be documented in a traceable manner.
The following tests must be planned:
Before commissioning the machine and after making changes, you must check
whether the safety functions are fulfilling their planned purpose and whether
persons are being adequately protected.
The regular tests of the safety laser scanner must fulfill certain minimum require‐
ments.
A test object is required for some thorough checks. An optically opaque cylinder with
a black surface can be used as a suitable test object. The diameter must match the
configured resolution.
4.6.1 Planning the thorough check during commissioning and in certain situations
Minimum requirements
T
he protective device and its application must be thoroughly checked in the following
situations:
Before commissioning
After changes to the configuration or the safety function
After changes to the mounting, the alignment or the electrical connection
After exceptional events, such as after manipulation has been detected, after
modification of the machine, or after replacing components
The thorough check ensures the following:
Compliance with all relevant regulations and effectiveness of the protective device
for all of the machine’s operating modes. This includes the following points:
°
compliance with standards
°
correct use of the protective device
°
suitable configuration and safety function
°
correct alignment
The documentation matches the state of the machine, incl. the protective device
The verified configuration report corresponds to the desired project planning (see
"Verifying configuration", page 126)
4 P
ROJECT PLANNING
70
O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET 8021219/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m