Version number Amendments and new functions
1.3.0
•
D
ata output: Accuracy of angle specification improved
•
Adaptation of detection behavior for optimized safety and avail‐
ability
In some cases, new system plugs are not suitable for older devices.
N
ew system plugs have a label which indicates the devices for which they are suitable.
Table 37: Compatibility
Label on the device Label on the system plug Compatible
– – Yes
– Only compatible with Rev ≥ 1.1.0 Information is available
fr
om your SICK subsidiary.
Rev 1.1.0 (or higher) – Yes
Rev 1.1.0 (or higher) Only compatible with Rev ≥ 1.1.0 Yes
13.3 Data sheet
13.3.1 microScan3 – PROFINET
Features
T
able 38: Features
microScan3 Core – PROFINET microScan3 Pro – PROFINET
Protective field range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 4.0 m, details: see "Sensing range", page 173
Devices with a max. protec‐
tive field range of 5.5 m
≤ 5.5 m, details: see "Sensing range", page 173
Devices with a max. protec‐
t
ive field range of 9.0 m
≤ 9.0 m, details: see "Sensing range", page 173
Scanning range of the refer‐
ence contour field
Same as protective field range, see "Sensing range", page 173
Scanning range of the con‐
tour detection field
Same as protective field range, see "Sensing range", page 173
Warning field range
Devices with a max. protec‐
t
ive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
tive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
t
ive field range of 9.0 m
≤ 64 m
Distance measurement range
Devices with a max. protec‐
tive field range of 4.0 m
≤ 40 m
Devices with a max. protec‐
t
ive field range of 5.5 m
≤ 40 m
Devices with a max. protec‐
tive field range of 9.0 m
≤ 64 m
Fields ≤ 8 ≤ 128
Simultaneously monitored fields
TECHNICAL DATA 13
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
165