When the start procedure is complete, the status LEDs and the display show the safety
la
ser scanner’s current operational status.
1 2 3 4
Figure 81: Status LEDs
T
able 19: Status LEDs
Number Function Color Meaning
1
OFF state Red Lights up red when at least one
s
afety output is in the OFF state.
2
ON state Green Lights up green when at least one
safety output is in the ON state.
3
Warning field Yellow Shines yellow if at least one warning
field is interrupted.
4
Restart interlock Yellow Setup with reset: Flashes if the
r
estart interlock has been triggered.
Configuration with automated restart
after a time: Lights up while the con‐
figured time to restart expires.
The OFF state and ON state LEDs can be found in multiple locations on the safety laser
sc
anner. 3 additional sets are arranged in pairs on the base of the optics cover. So the
LEDs can also be seen in many cases when it is not possible to see the display, e.g. due
to the mounting situation or because it is hidden from the operator’s position.
The device has different LEDs for every network interface. These network LEDs are
located below the display.
More information about what the LEDs mean and the symbols and information shown
on the display: see "Troubleshooting", page 149.
8.4 Check during commissioning and modifications
The test is intended to ensure that the hazardous area is monitored by the protective
de
vice and any attempted access to the hazardous area is prevented.
b
Carry out the checks specified in the test plan of the manufacturer of the machine
and the operating entity.
COMMISSIONING 8
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
135
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m

Related product manuals