EasyManuals Logo

SICK microScan3 User Manual

SICK microScan3
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #155 background imageLoading...
Page #155 background image
11.4.2 Event history
Overview
Figure 90: Event history
1
Data source
2
Available views
3
Navigation
The safety laser scanner stores data on important events. The event history displays
inf
ormation about the most recently stored events.
Event memory in the safety laser scanner
The safety laser scanner stores data on the following events:
Safety output switches to the OFF state.
An object is detected in a safety-related field.
For each object detection where a safety output switches to the OFF state, the safety
laser scanner stores the data from 10 scans. When the internal memory of the safety
laser scanner is full, the scan data of the oldest object detection is overwritten to store
a new object detection. The position and time of the object detection are retained.
The internal memory of the safety laser scanner is cleared when it is restarted.
TROUBLESHOOTING 11
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
155
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m