Configuring
6.6 Configuring the positioning axis/synchronous axis technology object
S7-1500 Motion Control V13 Update 3
126 Function Manual, 07/2014, A5E03879256-AC
Position parameter
Leadscrew pitch (select "Consider load gear and leadscrew pitch for encoder evaluation")
In this field, configure the distance by which the load is moved when the leadscrew
makes one revolution.
Leadscrew pitch (select "Consider load gear and leadscrew pitch for encoder evaluation")
In this field, configure the load distance for one motor revolution.
Linear - On the motor side
The encoder is mechanically connected with the load side of the gear.
Load gear
Number of motor revolutions / number of load revolutions
The gear ratio of the load gear is specified as the ratio between motor revolutions and
load revolutions. Specify here an integral number of motor revolutions and the resulting
number of load revolutions.
Select the same values for the number of motor revolutions and load revolutions, if no
load gear is present.
Position parameter
Leadscrew pitch
In this field, configure the distance by which the load is moved when the leadscrew
makes one revolution.
Linear - External Measuring System
An external measuring system provides the position values of the linear load motion.