EasyManua.ls Logo

Siemens SIMATIC S7-1500 Motion Control V13 - Errordetail Tags (External Encoder)

Siemens SIMATIC S7-1500 Motion Control V13
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.3 Tags of the technology object external encoder
S7-1500 Motion Control V13 Update 3
366 Function Manual, 07/2014, A5E03879256-AC
A.3.12
ErrorDetail tags (external encoder)
The tag structure <TO>.ErrorDetail.<tag name> contains the alarm number and the effective
local alarm reaction to the technology alarm that is currently pending at the technology
object.
A list of the technology alarms and alarm reactions can be found in the appendix,
Technology Alarms (Page 368).
Tags
Legend (Page 358)
Tag
Data type
Values
W
Description
ErrorDetail.
STRUCT
Number
UDINT
-
RON
Alarm number
Reaction DINT 0 to 5 RON Effective alarm reaction
0: No reaction
1: Stop with current dynamic values
2 Stop with maximum dynamic values
3: Stop with emergency stop ramp
4: Remove enable
5: Follow-up setpoints
For the external encoder technology object, only
alarm reactions 0 and 4 are possible.

Table of Contents