EasyManua.ls Logo

Siemens SIMATIC S7-1500 Motion Control V13 - Technology alarms

Siemens SIMATIC S7-1500 Motion Control V13
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.4 Technology alarms
S7-1500 Motion Control V13 Update 3
368 Function Manual, 07/2014, A5E03879256-AC
A.4
Technology alarms
A.4.1
Overview
The following table shows an overview of the technology alarms and the corresponding
alarm reactions. When a technology alarm occurs, evaluate the entire indicated alarm text, in
order to find the precise cause.
Legend
No. Number of the technology alarm
(corresponds to <TO>.ErrorDetail.Number)
Response Effective alarm reaction
(corresponds to <TO>.ErrorDetail.Reaction)
Error bit
Bit that is set in <TO>.ErrorWord when the technology alarm occurs
Warning bit
Bit that is set in <TO>.WarningWord when the technology alarm occurs
Restart To acknowledge the technology alarm, the technology object must be reinitialized
(restart).
Alarm text
Indicated alarm test (limited)
List of the technology alarms
No.
Response
Error bit
Warning bit
Restart
Alarm text
101 Remove enable X1 (Configuration-
Fault)
- X Error in the configuration.
104 Stop with maximum
dynamic values
X1 (Configuration-
Fault)
- - Error in the specification of software limit
switches.
105 Remove enable X1 (Configuration-
Fault)
- X Configuration mode (drive/actuator).
106 Remove enable X1 (Configuration-
Fault)
- X Configuration error in the drive actuator
driver.
107 Remove enable X1 (Configuration-
Fault)
- X Configuration error encoder.
108 Remove enable X1 (Configuration-
Fault)
- X Configuration error encoder driver.
109 Remove enable X1 (Configuration-
Fault)
- - Configuration error.
110 No reaction - X1
(Configuration-
Fault)
- Configuration is being internally adapted.
201
Remove enable
X0 (SystemFault)
-
-
Internal error.
202
No reaction
X0 (SystemFault)
-
-
Internal configuration error.
203 Remove enable X0 (SystemFault) - - Internal error. Please contact customer
service.

Table of Contents