Appendix
A.4 Technology alarms
S7-1500 Motion Control V13 Update 3
368 Function Manual, 07/2014, A5E03879256-AC
The following table shows an overview of the technology alarms and the corresponding
alarm reactions. When a technology alarm occurs, evaluate the entire indicated alarm text, in
order to find the precise cause.
No. Number of the technology alarm
(corresponds to <TO>.ErrorDetail.Number)
Response Effective alarm reaction
(corresponds to <TO>.ErrorDetail.Reaction)
Bit that is set in <TO>.ErrorWord when the technology alarm occurs
Bit that is set in <TO>.WarningWord when the technology alarm occurs
Restart To acknowledge the technology alarm, the technology object must be reinitialized
Indicated alarm test (limited)
List of the technology alarms
101 Remove enable X1 (Configuration-
- X Error in the configuration.
104 Stop with maximum
X1 (Configuration-
- - Error in the specification of software limit
105 Remove enable X1 (Configuration-
- X Configuration mode (drive/actuator).
106 Remove enable X1 (Configuration-
- X Configuration error in the drive actuator
107 Remove enable X1 (Configuration-
- X Configuration error encoder.
108 Remove enable X1 (Configuration-
- X Configuration error encoder driver.
109 Remove enable X1 (Configuration-
- - Configuration error.
110 No reaction - X1
(Configuration-
- Configuration is being internally adapted.
Internal configuration error.
203 Remove enable X0 (SystemFault) - - Internal error. Please contact customer