11.2 S7-1500 Motion Control V1
S7-1500 Motion Control V13 Update 3
318 Function Manual, 07/2014, A5E03879256-AC
11.2.8
MC_Reset
11.2.8.1
MC_Reset: Acknowledge alarms, restart technology objects V1
Description
All technology alarms that can be acknowledged in the user program are acknowledged with
the Motion Control instruction "MC_Reset". Acknowledgment also resets the "Error" and
"Warning" bits in the technology data block.
Technology objects are reinitialized (restarted) using the Motion Control instruction
"MC_Reset" with "Restart" = TRUE. Upon restart of the technology object, the new
configuration data are applied in the technology data block.
Applies to
Positioning axis
Speed axis
External encoder
Requirements
The cause of the error for a pending technology alarm has been resolved.
For a restart, the technology object must be disabled.
("MC_Power.Status" = FALSE and "MC_Power.Busy" = FALSE)
Override response
Parameter "Restart" = FALSE:
Processing of the instruction "MC_Reset" can be aborted by other Motion Control jobs.
The MC_Reset job does not abort any running Motion Control jobs.
Parameter "Restart" = TRUE:
The processing of the instruction "MC_Reset" with parameter "Restart" = TRUE cannot
be aborted by any other Motion Control job.