Instructions   
11.1 S7-1500 Motion Control V2 
  S7-1500 Motion Control V13 Update 3 
266  Function Manual, 07/2014, A5E03879256-AC 
●  Synchronous axis 
●  Positioning axis 
●  The technology object has been configured correctly. 
●  The technology object is enabled. 
The "MC_MoveSuperimposed" job is aborted by: 
●  Disabling the axis with "MC_Power.Enable" = FALSE 
●  "MC_Home" job "Mode" = 3, 5 
●  "MC_Halt" job 
●  "MC_MoveAbsolute" job 
●  "MC_MoveRelative" job 
●  "MC_MoveVelocity" job 
●  "MC_MoveJog" job 
●  "MC_GearIn" job 
●  "MC_MoveSuperimposed" job 
Starting a "MC_MoveSuperimposed" job aborts an active "MC_MoveSuperimposed" job.