EasyManua.ls Logo

Siemens SIMATIC S7-1500 Motion Control V13 - Page 335

Siemens SIMATIC S7-1500 Motion Control V13
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.2 Tags of the positioning axis/synchronous axis technology object
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
335
Tag
Data type
Values
W
Description
DriveParameter.
ReferenceSpeed LREAL 0.0 to 1.0E12 RES Reference value (100%) for the setpoint speed of
the drive (N-set)
The setpoint speed is transmitted in the
PROFIdrive frame as a standardized value from -
200% to 200% of the "ReferenceSpeed".
For setpoint specification via an analog output,
the analog output can be operated in the range
from -117% to 117%, insofar as the drive permits
this.
MaxSpeed LREAL 0.0 to 1.0E12 RES Maximum value for the setpoint speed of the
drive (N-set)
(PROFIdrive: MaxSpeed ≤ 2 × ReferenceSpeed
Analog setpoint: MaxSpeed ≤ 1.17 × Refer-
enceSpeed)
See also
Evaluating the technology data block (Page 173)

Table of Contents