Operation
6.6 Communication according to PROFIdrive
Inverter chassis units
246 Operating Instructions, 07/2016, A5E00331449A
The structure is as follows:
Header-Byte
3 0 ... 244 (slot number ≙ drive object)
0 ... 31 (sequence number)
1)
5 DS0 (byte 0) 0 0 0 0 1
2)
0 1
3)
1
4)
5)
6)
6)
6)
6)
= 0x45 (ChannelTypeID = SINAMICS)
= 24 (number of diagnostic bits/channel)
12 Channel Error
Vector
0 0 0 0 0 0 0 Channel 0
Channel
-related diag-
nostics
15 0 0 0 0 Err 19 Err 18 Err 17 Err 16
Alarm_Specifier
1 ≙ error has occurred and the slot is not OK
2 ≙ error is resolved and the slot is OK
3 ≙ error is resolved and the slot is not okay
Channel fault present
= 1; as long as the drive object has an error condition
Internal fault
= 1; as long as the drive object has an error condition
Module fault
= 1; as long as the drive object has an error condition
Channel information present
= 1; ≙ DS1 exists
Type class of module
Further information about PROFIdrive communication
Further information about PROFIdrive communication
For more information about PROFIdrive communication, refer to "PROFIdrive
communication" in the accompanying "SINAMICS S120 Function Manual".