Operation 
  6.11 Communication via MODBUS TCP 
Inverter chassis units 
Operating Instructions, 07/2016, A5E00331449A 
303 
ON/OFF text 
or Value range 
40343  Output voltage  R  V  1  0 … 65535  r0025 
3)
Technology controller enable 
40501  Technology controller MOP  R/W  %  100  -200.0 … 200.0  p2240 
Adapt technology controller 
1)
40510  Time constant for actual-value filters 
of the technology controller 
R/W  -  100  0.00 … 60.0  p2265 
40511  Scaling factor for actual value of the 
R/W  %  100  0.00 … 500.00  p2269 
40512  Proportional amplification of the tech-
R/W  -  1000  0.000 … 65.535  p2280 
40513  Integral time of the technology con-
R/W  s  1  0 … 60  p2285 
40514  Time constant D-component of the 
R/W  -  1  0 … 60  p2274 
Max. limit of technology controller 
Min. limit technology controller 
40520  Effective setpoint acc. to internal 
technology controller MOP ramp-
R  %  100  -100.0 … 100.0  r2250 
40521  Actual value of technology controller 
R  %  100  -100.0 … 100.0  r2266 
Output signal technology controller 
 
The technology controller parameters can only be accessed if, in the STARTER project, also the "Technology controller" 
function module is activated.