Setpoint channel and closed-loop control
7.3 V/f control
Inverter chassis units
336 Operating Instructions, 07/2016, A5E00331449A
Figure 7-10 Slip compensation
Resonance damping and slip compensation
r0330
p1334
Slip compensation start frequency
p1335
Slip compensation, scaling
p1335 = 0.0%: slip compensation is deactivated.
p1335 = 100.0%: slip is fully compensated.
p1336
Slip compensation limit value
r1337
CO: Actual slip compensation
p1351
CO: Motor holding brake start frequency