Technical specifications   
12.2 General specifications 
  Inverter chassis units 
560  Operating Instructions, 07/2016, A5E00331449A 
Table 12- 5  Derating factor of the output current as a function of the pulse frequency for devices with a rated pulse fre-
quency of 1.25 kHz 
Output current  
at 1.25 kHz 
Derating factor at the pulse frequency 
Supply voltage 3-phase 380 VAC ... 480 VAC 
1GE37-5AAx  400  745  83%  72%  64%  60%  40% 
1GE41-0AAx  560  985  92%  87%  70%  60%  50% 
Supply voltage 3-phase 500 VAC ... 600 VAC 
Supply voltage 3 AC 660 ... 690 V 
1GH32-2AAx  200  215  92%  87%  70%  60%  40% 
1GH37-4AAx  710  735  87%  79%  64%  55%  35% 
 
 
Note 
Derating factors for pulse frequencies in the range between two fixed values 
For pulse frequencies in the range between the specified fixed values, the relevant derating 
factors can be determined by linear interpolation.