EasyManua.ls Logo

Siemens SINAMICS G130 - Page 566

Siemens SINAMICS G130
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
12.3 Technical specifications
Inverter chassis units
566 Operating Instructions, 07/2016, A5E00331449A
Article number
6SL3310-
1GE33-8AAx
1GE35-0AAx
1GE36-1AAx
Recommended fuses
- Line protection
without semiconductor protection
Rated current
frame size to IEC 60269
- Line and semiconductor protection
6)
Rated current
Frame size to IEC 60269
A
A
3NA3260
400
3
3NE1334-2
450
2
3NA3372
630
3
3NE1436-2
630
3
3NA3475
800
4
3NE1438-2
800
3
Minimum short-circuit current
7)
A
4400
8000
10000
1)
Rated output of a typ. 6-pole standard induction motor based on I
L
or I
H
at 400 V 3 AC 50 Hz.
2)
Rated output of a typ. 6-pole standard induction motor based on I
L
or I
H
at 460 V 3 AC 60 Hz.
3)
The base-load current I
L
is based on a duty cycle of 110% for 60 s or 150% for 10 s with a duty cycle duration of 300 s
(see "Overload capability").
4)
The base-load current I
H
is based on a duty cycle of 150% for 60 s or 160% for 10 s with a duty cycle duration of 300 s
(see "Overload capability").
5)
If the auxiliary supply is to be fed in separately from the load supply, e.g., if the control should be able to continue com-
munication if the line voltage fails.
6)
It is mandatory that the specified fuses are used to achieve a UL-approved system.
7)
The minimum current required to reliably trigger 3NE1 protective devices.