EasyManua.ls Logo

Siemens SINAMICS G130 - Page 598

Siemens SINAMICS G130
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.2 Parameter macros
Inverter chassis units
598 Operating Instructions, 07/2016, A5E00331449A
Parameter macro p0700 = 4: PROFIdrive+TM31 (70004)
This macro is used to set the PROFIdrive interface and terminal block TM31 as the
command source.
Table A- 5 Parameter macro p0700 = 4: PROFIdrive+TM31
Sink
Source
Parameter
Description
DO
Parameter
Description
DO
p0840[0]
ON/OFF1
Vector
r2090.0
PZD 1 bit 0
Vector
p0844[0]
No OFF2_1
Vector
r2090.1
PZD 1 bit 1
Vector
p0845[0] No OFF2_2 Vector r4022.4 TM31 DI4 TM31
p0848[0]
No OFF3_1
Vector
r2090.2
PZD 1 bit 2
Vector
p0849[0] No OFF3_2 Vector r4022.5 TM31 DI5 TM31
p0806
Inhibit LOCAL mode
Vector
0
Vector
p0810
Changeover CDS bit 0
Vector
0
Vector
p0852
Enable operation
Vector
r2090.3
PZD 1 bit 3
Vector
p0854
Control request
Vector
r2090.10
PZD 1 bit 10
Vector
p0922
Profibus PZD telegram selection
Vector
999
Free telegram configuration
p1020
FSW bit 0
Vector
0
Vector
p1021
FSW bit 1
Vector
0
Vector
p1035
MOP raise
Vector
r2090.13
PZD 1 bit 13
Vector
p1036
MOP lower
Vector
r2090.14
PZD 1 bit 14
Vector
p1113
Direction of rotation reversal
Vector
r2090.11
PZD 1 bit 11
Vector
p1140
Enable RFG
Vector
r2090.4
PZD 1 bit 4
Vector
p1141
Start RFG
Vector
r2090.5
PZD 1 bit 5
Vector
p1142
Enable nsetp
Vector
r2090.6
PZD 1 bit 6
Vector
p2103
Acknowledge fault 1
Vector
r2090.7
PZD 1 bit 7
Vector
p2104
Acknowledge fault 2
Vector
r4022.3
TM31 DI3
TM31
p2106
Ext. fault_1
Vector
r4022.6
TM31 DI6
TM31
p2107 Ext. fault_2 Vector 1 Vector
p2112
Ext. alarm_1
Vector
r4022.11
TM31 DI11
TM31
p2116
Ext. alarm_2
Vector
1
Vector
p0738
DI/DO8
CU
0
CU
p0748.8
Invert DI/DO8
CU
0
Not inverted
p0728.8
Set DI/DO8 input or output
CU
1
Output
p0739 DI/DO9 CU 0 CU
p0748.9
Invert DI/DO9
CU
0
Not inverted
p0728.9
Set DI/DO9 input or output
CU
1
Output
p0740
DI/DO10
CU
0
CU
p0748.10
Invert DI/DO10
CU
0
Not inverted
p0728.10
Set DI/DO10 input or output
CU
1
Output
p0741
DI/DO11
CU
0
CU
p0748.11
Invert DI/DO11
CU
0
Not inverted
p0728.11
Set DI/DO11 input or output
CU
1
Output

Table of Contents

Other manuals for Siemens SINAMICS G130

Related product manuals