EasyManua.ls Logo

Siemens SINUMERIK 802D sl - Page 184

Siemens SINUMERIK 802D sl
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Modes, Program Operation (K1)
10.3 Processing a part program
Turning, Milling, Nibbling
184 Function Manual, 11/2012, 6FC5397-1CP10-5BA0
Bit 4 = 1 is set, after First start after search run event
The following constraint applies for Bit 0 == 1 (program event after part program start):
If the program event ends with the part program command "RET", then RET always leads
to an executable block (analogous to M17).
There is no new behavior for Bit 0 == 0, i.e. RET is interpreted in the interpreter and does
not lead to an "executable block".
No sequences for start/end of part program are passed:
If a user ASUB is started from the reset status, the described sequences for the event for
start/end of part program are not passed.
Settable Prog-Event properties
Machine data MD20109 PROG_EVENT_MASK_PROPERTIES can be used to define
further properties of "event-driven program calls" for specific channels:
Bit0 = 0: An ASUB started from the RESET channel state is followed by an "event-
driven program call" as in earlier versions
Bit0 = 1: An ASUB started from the RESET channel state is not followed by an "event-
driven program call"
With the Part program start:
/_N_CMA_DIR/_N_PROG_EVENT_SPF is executed as a subroutine.
_N_PROG_EVENT_SPF must be ended with M17 or RET. A return by means of REPOS
command is not permitted and triggers alarm 16020 "Repositioning not possible".
Error with operator panel reset or after ramp-up:
If EMERGENCY STOP or an operating mode / NCK error is still present when the operator
panel is reset or after rampup, then _N_PROG_EVENT_SPF will only be processed after
EMERGENCY STOP has been acknowledged or the error has been acknowledged in the
channel.
Assignment example
MD20106 PROG_EVENT_IGN_SINGLEBLOCK = 'H1F'
MD20107 PROG_EVENT_IGN_INHIBIT = 'HC'
MD20109 PROG_EVENT_MASK_PROPERTIES = 'H1'
Event programs
Example for call by all events
MD20108 PROG_EVENT_MASK = 'H0F' (event-driven program call),
i.e. call of _N_PROG_EVENT_SPF during part program start, part program end, operator
panel reset and ramp-up:
PROC PROG_EVENT DISPLOF

Table of Contents