Various Interface Signals (A2)
1.7 Signals from PLC
Turning, Milling, Nibbling
40 Function Manual, 11/2012, 6FC5397-1CP10-5BA0
1.7 Signals from PLC
Commissioning mode
The ramp-up modes are signaled via bit 0 and bit 1 (VB1800 1000) in the user interface.
Commissioning mode VB1800 1000.1 VB1800 1000.0
Normal rampup 0 0
Ramp-up with default values 0 1
Ramp-up with saved data 1 0