Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
7.4 Closed-loop control
Turning, Milling, Nibbling
Function Manual, 11/2012, 6FC5397-1CP10-5BA0
133
Consistency check
While the SINUMERIK 802D sl is powering up, a consistency check is performed on the
parameters for cyclic PROFIBUS communication that are relevant for process data
configuration:
NC: MD13060 DRIVE_TELEGRAM_TYPE[n] (drive telegram type)
Drive: p0922 (PROFIdrive telegram selection)
If the drive telegram type in MD13060 is different from the one defined in p0922, alarm
26015 "Axis %1 machine data %2[%3] value not permissible" is output (in this case, %2
corresponds to the identifier for MD13060).
Application examples
System variables during synchronization with a modal effect:
ID=1 WHENEVER TRUE DO $R0=$VA_LOAD[X]
System variables in a part program:
...
WHENEVER $VA_LOAD[X]>80 DO $AC_OVR=80
G1 G90 X200 F10000
...
7.4 Closed-loop control
General
The closed-loop control of an axis consists of the current and speed control loop of the drive
plus a higher-level position control loop in the NC.
The speed and current control are described in:
Reference:
/FH1/ Function Manual SINAMICS S120, Section "Operating modes"

Table of Contents

Other manuals for Siemens SINUMERIK 802D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 802D sl and is the answer not in the manual?

Siemens SINUMERIK 802D sl Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 802D sl
CategoryController
LanguageEnglish

Related product manuals