Press this softkey to confirm and proceed to one
-key auto tuning.
Press this key on the MCP and the drive tuning starts automatically. Since the axes traverse
during the tuning process, make sure you take proper prec
autions to avoid personal injury
After the drive tuning finishes successfully, the tuning results appear on the screen in the
form of a p
arameter list, for example:
It may be the case that some parameters after tuning display the same values as
those before tuning, since up to six decimal places can be displayed in the parameter list as
above.
the tuning results of other tuned axis/axes (if any) with these softkeys.
Press this softkey to save the tuning results and write the modified parameters in
to the
Pressing this softkey aborts the tuning and deletes the results.
After it returns automatically to the main screen of drive tuning, press this softkey to proceed
to the next step.
The following softkey operation is also available on this screen:
Saves the trace files during the tuning process to a USB flash disk
(if inserted)
Note
For the machine data that are changeable only with a manufacturer password, the settings made during drive tuning cannot
be
restored after an NC restart in case of power failure or unexpected abortion of the tuning process.