Internal and configurable pickup and dropout delay
Modifiable message texts.
Synchrocheck (only 7SJ623, 7SJ624, 7SJ625, 7SJ626 and 7SJ64)
Verification of the synchronous conditions before reclosing after three-pole tripping
Fast measurement of the voltage difference ΔV, the phase angle difference Δϕ and the frequency differ-
ence Δf
Alternatively, check of the de-energized state before reclosing
Switching possible for asynchronous system conditions with prediction of the synchronization time (only
7SJ64)
Setable minimum and maximum voltage
Verification of the synchronous conditions or de-energized state also possible before the manual closing
of the circuit breaker, with separate limit values
Measurement also possible via transformer without external intermediate matching transformer
Measuring voltages optionally phase–to–phase or phase–to–ground.
RTD box
Detection of any ambient temperatures or coolant temperatures by means of an external RTD box and
external temperature sensors.
Phase Rotation
Selectable ABC or ACB by setting (static) or binary input (dynamic).
Circuit-Breaker Maintenance
Statistical methods to help adjust maintenance intervals for CB contacts according to their actual wear
several independent subfunctions have been implemented(ΣΙ-procedure, ΣΙ
x
-procedure, 2P-procedure
and Ι
2
t-procedure)
Acquisition and conditioning of measured values for all subfunctions operates phase-selective using one
procedure-specific threshold per subfunction.
User Defined Functions
Freely programmable linking of internal and external signals in order to implement user-defined logic
functions
All standard logic functions (AND, OR, NOT, EXCLUSIVE-OR, etc.)
Time delays and limit value interrogations
Processing of measured values, including zero suppression, adding a knee curve for a transducer input,
and live-zero monitoring.
Breaker Control
Circuit breakers can be opened and closed via specific process control keys (models with graphic displays
only), the programmable function keys on the front panel, via the system interface (e.g. by SICAM or
SCADA), or via the front PC interface using a personal computer with DIGSI)
Feedback of switching states via the switch auxiliary contacts
Plausibility monitoring of the circuit breaker position and check of interlocking conditions.
Introduction
1.3 Characteristics
SIPROTEC 4, 7SJ62/64, Manual 29
C53000-G1140-C207-8, Edition 08.2016

Table of Contents

Other manuals for Siemens SIPROTEC 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 4 and is the answer not in the manual?

Siemens SIPROTEC 4 Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 4
CategoryProtection Device
LanguageEnglish

Related product manuals