Profibus FO (FMS and DP)
FO connector type ST connector
Single ring / double ring according to the order for FMS; for DP only
double ring available
Connection for flush-mounted
casing
Rear panel, mounting location “B”
Connection for surface-mounted
casing
in console housing on the case bottom via RS485 and external RS485/
optical converter
Transmission Speed up to 1.5 MBd
recommended: > 500 kBd with normal casing
≤ 57 600 Bd at detached operator panel
Optical Wavelength λ = 820 nm
Laser Class 1 according to EN
60825-1/-2
using glass fiber 50/125 μm or using glass fiber 62.5/125 μm
Permissible Optical Link Signal
Attenuation
max. 8 dB, with glass fiber 62.5/125 μm
Maximum Distance of Transmission max. 0.93 miles (1.5 km)
DNP3.0 / MODBUS RS485
Connection for flush-mounted
casing
Rear panel, mounting location “B”, 9-pin DSUB miniature connector
Connection for surface-mounted
casing
at the housing mounted case on the case bottom
Test Voltage (PELV) AC 500 V; 50 Hz
Transmission Speed up to 19,200 Bd
Maximum Distance of Transmission max. 0.62 miles (1 km)
DNP3.0 / MODBUS / FO
FO connector type ST–Connector Receiver/Transmitter
Connection for flush-mounted
casing
Rear panel, mounting location “B”
Connection for surface-mounted
casing
not available
Transmission Speed up to 19,200 Bd
Optical Wavelength λ = 820 nm
Laser Class 1 according to EN
60825-1/-2
using glass fiber 50/125 μm or using glass fiber 62.5/125 μm
Permissible Optical Link Signal
Attenuation
max. 8 dB, with glass fiber 62.5/125 μm
Maximum Distance of Transmission max. 0.93 miles (1.5 km)
Ethernet electrical (EN100) for DIGSI, IEC61850, DNP3 TCP, PROFINET
Connection for flush-mounted
casing
rear panel, mounting location “B”; 2 x RJ45 socket contact 100BaseT acc.
to IEEE802.3
Connection for surface-mounted
casing
in console housing at case bottom
Test voltage (reg. socket) (PELV) 500 V; 50 Hz
Transmission speed 100 MBit/s
Bridgeable distance 65.62 feet (20 m)